DS30 - DS60 - DS100 |
110.25 |
Lockable Disconnecting Means |
AFTR1 |
210.12(A) |
Arc-Fault Circuit Interrupter Protection — Outlet Branch Circuit (OBC) AFCI Receptacle Allowances |
AFTR2 |
210.12(A) |
Arc-Fault Circuit Interrupter Protection — Outlet Branch Circuit (OBC) AFCI Receptacle Allowances |
AFRBF |
210.12(A) |
Arc-Fault Circuit Interrupter Protection — Outlet Branch Circuit (OBC) AFCI Receptacle Allowances |
AFTR1 |
210.12(A) |
Arc-Fault Circuit-Interrupter Protection in Kitchens and Laundry Areas |
AFTR2 |
210.12(A) |
Arc-Fault Circuit-Interrupter Protection in Kitchens and Laundry Areas |
AFRBF |
210.12(A) |
Arc-Fault Circuit-Interrupter Protection in Kitchens and Laundry Areas |
AFRBF |
210.12(B) |
AFCI Protection — Branch Circuit Extensions and Modifications |
AFTR1 |
210.12(B) |
AFCI Protection — Branch Circuit Extensions and Modifications |
AFTR2 |
210.12(B) |
AFCI Protection — Branch Circuit Extensions and Modifications |
AFTR1 |
210.12(C) |
AFCI Protection Required in Dormitories |
AFTR2 |
210.12(C) |
AFCI Protection Required in Dormitories |
AFRBF |
210.12(C) |
AFCI Protection Required in Dormitories |
EVB22 |
210.17 |
Electric Vehicle Individual Branch Circuit |
EVB32 |
210.17 |
Electric Vehicle Individual Branch Circuit |
EVB40 |
210.17 |
Electric Vehicle Individual Branch Circuit |
W7599-T |
210.52 (E)(3) |
Receptacles on Decks, Porches and Balconies |
W7899-T |
210.52 (E)(3) |
Receptacles on Decks, Porches and Balconies |
T7599 |
210.52 (G) |
Receptacles in Garages, Basements and Accessory Buildings |
T7899 |
210.52 (G) |
Receptacles in Garages, Basements and Accessory Buildings |
CR15 |
210.64 |
Receptacle Required for Service Equipment |
CR20 |
210.64 |
Receptacle Required for Service Equipment |
T7599 |
210.8(A)(10) |
GFCI Protection for Receptacles in Dwelling Unit Laundry Areas |
T7899 |
210.8(A)(10) |
GFCI Protection for Receptacles in Dwelling Unit Laundry Areas |
T7599 |
210.8(A)(7) |
GFCI Protection for Receptacles Around Dwelling Unit Sinks, Including Kitchen Sinks |
T7899 |
210.8(A)(7) |
GFCI Protection for Receptacles Around Dwelling Unit Sinks, Including Kitchen Sinks |
T7599 |
210.8(A)(9) |
GFCI Protection for Receptacles Around Dwelling Unit Shower Stalls and Bathtubs |
T7899 |
210.8(A)(9) |
GFCI Protection for Receptacles Around Dwelling Unit Shower Stalls and Bathtubs |
WR599 |
210.8(B)(3) |
GFCI Protection for Receptacles on Rooftops |
WR899 |
210.8(B)(3) |
GFCI Protection for Receptacles on Rooftops |
N7599 |
210.8(B)(8) |
GFCI Protection of Receptacles in Garages, Service Areas and Similar Areas |
N7899 |
210.8(B)(8) |
GFCI Protection of Receptacles in Garages, Service Areas and Similar Areas |
T7599 |
210.8(D) |
GFCI Protection for Kitchen Dishwasher Branch Circuit |
T7899 |
210.8(D) |
GFCI Protection for Kitchen Dishwasher Branch Circuit |
DS30 - DS60 - DS100 |
225.36 & 225.38 |
Disconnect Type — Building or Structure Supplied by Feeder(s) or Branch Circuit |
52120 |
240.21(B)(1)(1)b. |
Taps Not Over 10 Feet Long — Exception For Surge Protective Devices |
57240 |
240.21(B)(1)(1)b. |
Taps Not Over 10 Feet Long — Exception For Surge Protective Devices |
T5325 |
250.130(C)(4) |
Equipment Grounding Conductor Extensions |
T5825 |
250.130(C)(4) |
Equipment Grounding Conductor Extensions |
5601 |
404.10(B) |
Mounting Snap Switches — Must Use Correct Screws |
5603 |
404.10(B) |
Mounting Snap Switches — Must Use Correct Screws |
T5325 |
406.12 |
Tamper-Resistant Receptacle Exemptions |
T5825 |
406.12 |
Tamper-Resistant Receptacle Exemptions |
AFTR1 |
406.4(D) |
AFCI and GFCI Replacement Receptacles |
AFTR2 |
406.4(D) |
AFCI and GFCI Replacement Receptacles |
AFRBF |
406.4(D) |
AFCI and GFCI Replacement Receptacles |
T5320 |
406.5 |
Mounting Receptacles — Correct Screws Required |
T5325 |
406.5 |
Mounting Receptacles — Correct Screws Required |
25249 |
406.5(E) & (F) |
Receptacles in the Face-Up Position in Countertops and Similar Surfaces |
5249 |
406.5(E) & (F) |
Receptacles in the Face-Up Position in Countertops and Similar Surfaces |
5980 |
406.9(B)(1) |
Receptacles in Wet Locations Must Have While-In-Use Covers Listed as “Extra-Duty” |
5981 |
406.9(B)(1) |
Receptacles in Wet Locations Must Have While-In-Use Covers Listed as “Extra-Duty” |
WR599 |
422.23 |
Tire Inflation and Vacuum Machines — GFCI Protection Required |
WR899 |
422.23 |
Tire Inflation and Vacuum Machines — GFCI Protection Required |
T7599 |
422.5 |
GFCI’s For Appliances Must Be Readily Accessible |
T7899 |
422.5 |
GFCI’s For Appliances Must Be Readily Accessible |
16262-IG |
517.16 |
Isolated Ground Receptacles Not Allowed in Patient Care Areas, but Permitted in Other Areas of Health Care Facilities |
16362-IG |
517.16 |
Isolated Ground Receptacles Not Allowed in Patient Care Areas, but Permitted in Other Areas of Health Care Facilities |
80703 |
517.18(A) |
General Care Areas in Health Care Facilities — Patient Bed Locations — Critical Branch Receptacles Must Have Distinctive Color or Marking |
16262-SG |
517.18(B) |
General Care Locations Within Health Care Facilities — Number of Receptacles Increased |
16362-SG |
517.18(B) |
General Care Locations Within Health Care Facilities — Number of Receptacles Increased |
16262-SG |
517.18(C) |
Tamper-Resistant Receptacles in General Care Pediatric Locations |
16362-SG |
517.18(C) |
Tamper-Resistant Receptacles in General Care Pediatric Locations |
16262-SG |
517.19(B) |
Critical Care Locations Within Health Care Facilities — Number of Receptacles Increased |
16362-SG |
517.19(B) |
Critical Care Locations Within Health Care Facilities — Number of Receptacles Increased |
16262-SG |
517.19(C) |
Operating Rooms Within Health Care Facilities — Number of Receptacles Increased |
16362-SG |
517.19(C) |
Operating Rooms Within Health Care Facilities — Number of Receptacles Increased |
7313 |
551.71 |
Quantity and Types of Receptacles at RV Parks |
COVER-S |
600.6(A)(1) |
Disconnect Required at Point Where Circuit Enters Sign |
EVB22 |
625 |
Reorganization and Expansion of Article 625 Covering Electric Vehicle Supply Equipment (EVSE) |
EVB32 |
625 |
Reorganization and Expansion of Article 625 Covering Electric Vehicle Supply Equipment (EVSE) |
EVB40 |
625 |
Reorganization and Expansion of Article 625 Covering Electric Vehicle Supply Equipment (EVSE) |
EVB22 |
625.44 |
Electric Vehicle Supply Equipment Connections |
EVB32 |
625.44 |
Electric Vehicle Supply Equipment Connections |
EVB40 |
625.44 |
Electric Vehicle Supply Equipment Connections |
W7599-T |
680.21(C) |
GFCI Protection for Single-Phase Pool Pump Motors |
W7899-T |
680.21(C) |
GFCI Protection for Single-Phase Pool Pump Motors |
W7599-T |
680.22(A)(1) |
Required Receptacles Near All Pools — Not Just Dwelling Unit Pools |
W7899-T |
680.22(A)(1) |
Required Receptacles Near All Pools — Not Just Dwelling Unit Pools |
W7599-T |
680.22(A)(2) |
Pool Pump Receptacle |
W7899-T |
680.22(A)(2) |
Pool Pump Receptacle |
WR599 |
694.7(E) |
GFCI Protection for Wind Turbine Maintenance Receptacles |
WR899 |
694.7(E) |
GFCI Protection for Wind Turbine Maintenance Receptacles |
52120 |
700.8 |
Surge Protection Devices Required for Emergency Systems |
57240 |
700.8 |
Surge Protection Devices Required for Emergency Systems |